Key takeaways

  • Destoners are sized on wheat capacity in t/h, not screen width — the same width has B variants with 60% more capacity.
  • Air volume, deck angle and amplitude must be tuned together; changing one alone destroys separation.
  • Verify performance quarterly with the 200-stone spike test — anything below 95% removal means re-tuning or screen replacement.

Why the destoner is the machine people get wrong

Screens are intuitive: wheat passes over holes, small things fall through. Destoners are not. They separate particles of the same size by density, using a fluidised bed created by air passing up through a vibrating deck.

Three parameters are coupled:

Parameter Effect
Air volume Fluidises the bed; too little and nothing separates, too much and wheat blows out with the stones
Deck amplitude Agitates the bed; too little and it does not stratify
Deck angle Controls residence time and stone travel direction

Change one and you must re-tune the other two. This is why destoners are often found running badly — someone adjusted the air “to stop blowing wheat out” and never re-tuned the rest.

The two capacity families

Haiyun’s TQSF range has two families on overlapping screen widths:

Model Screen width Capacity (wheat) Air volume
TQSF60 60 cm 3–5 t/h 4,500 m³/h
TQSF80 80 cm 5–7 t/h 6,000 m³/h
TQSF100 100 cm 7–9 t/h 8,000 m³/h
TQSF125 125 cm 9–11 t/h 10,200 m³/h
TQSFB4125 125 cm 15–18 t/h 12,000 m³/h
TQSF150 150 cm 11–14 t/h 12,000 m³/h
TQSFB150 150 cm 18–20 t/h 15,000 m³/h
TQSF175 175 cm 14–18 t/h 15,000 m³/h
TQSF200 200 cm 16–20 t/h 17,000 m³/h
TQSF250 250 cm 20–22 t/h 20,400 m³/h

Note the bold rows: TQSFB4125 delivers 64% more capacity than TQSF125 on the identical 125 cm width. The difference is air volume and deck geometry.

When to choose a B variant: when floor space is the constraint rather than headroom, or when you are retrofitting a higher-capacity line into an existing building.

When not to: B variants need 20% more air, which means a larger fan and more power. If space is available, the standard model is more efficient per tonne.

Sizing rule

Destoner capacity ≥ 1.3 × cleaning line throughput

A 30 t/d plant with cleaning at 5 t/h needs 6.5 t/h of destoner capacity → TQSF100.

Do not size on mill throughput. Cleaning runs ahead of milling, and during harvest intake the line may run at 1.5× nominal for hours.

Air supply

The destoner’s fan is usually supplied with the machine, but check:

  • Static pressure must match the deck resistance at the specified air volume
  • Duct length beyond 3 m adds pressure drop and reduces effective volume
  • Air quality — dusty recirculated air blinds the deck and reduces fluidisation

If you share a fan with other equipment, verify the destoner still gets its rated volume. Shared fans are a common cause of poor destoning.

The 95% field test

Quarterly, do this:

  1. Count out exactly 200 clean field stones (or glass beads of similar size)
  2. Mix them into 20 kg of clean wheat
  3. Run the wheat through the destoner at production rate
  4. Collect and count stones in the stone outlet and in the accepted wheat

Target: 190+ stones in the stone outlet, fewer than 10 in the accepted wheat (95% removal).

Results and actions:

Removal rate Action
> 97% Excellent
95–97% Acceptable
90–95% Re-tune air volume and deck angle
< 90% Inspect screen cloth for wear or holes; replace if needed

Wheat loss in the stone outlet should be under 10 kernels per 100 stones. More than that means the air volume is too high and you are blowing good wheat out with the stones.

Maintenance

Item Interval
Deck screen inspection Weekly
Screen replacement When holes or wear exceed 10% of area
Air volume check Monthly
Fan bearing grease 500 hours
Suspension springs Annual inspection

The deck screen is the wearing part. A hole in the deck lets wheat fall into the stone channel, which shows up as high wheat loss in the stone outlet — a symptom often misdiagnosed as excessive air.

Answers

Questions on this topic

Straight answers to the questions engineers and mill owners actually ask us during plant sizing. If your case is not covered, send the wheat specification and your target tonnage.

Ask an engineer →
How do I size a destoner?
Match its wheat capacity to your cleaning line throughput with 30% margin. A 30 t/d plant cleaning at 5 t/h needs a TQSF100 (7–9 t/h) rather than a TQSF60 (3–5 t/h).
What is the difference between TQSF125 and TQSFB4125?
The B variant uses a larger air volume and a steeper deck to reach 15–18 t/h on the same 125 cm screen width, versus 9–11 t/h for the standard version.
How do I know if my destoner is working?
Take a 1 kg sample from the stone outlet. It should be almost entirely stones. More than 10 wheat kernels per 100 stones means the air volume is too high or the deck angle is wrong.

Next step

Send your tonnage. Get a flow sheet in 12 working hours.

Send us: daily capacity target, wheat type and quality, available building dimensions, and local power supply. We reply within 12 working hours with a preliminary flow sheet, equipment list and budget range — no obligation.